Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aust Endod J ; 49(3): 690-699, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37363860

RESUMO

The effect of ultrasonic activation (UA) on marginal adaptation, intratubular penetration and bond strength provided by three calcium silicate-based sealers was evaluated. Ninety-six distobuccal root canals of maxillary molars were randomly divided into 8 groups (n = 12) according to the sealer and UA application: EndoSequence BC sealer (ESBC), Sealer Plus BC (SPBC) and Bio-C Sealer (BCS), using AH Plus (AH) as a control group. The specimens were sectioned at 2, 4 and 6 mm from the apex. The data were statistically analysed using Kruskall-Wallis, Dunn, Mann-Whitney and chi-squared tests. UA improved the marginal adaptation of ESBC (6 mm), SPBC (all levels), BCS (2/4 mm) and AH (4 mm) (p < 0.05); the bond strength of SBPC (2 mm) and BCS (6 mm) were also improved (p < 0.05). The UA of endodontic silicate-based sealers improved the marginal adaptation in all levels and the bond strength of SBPC and BCS sealer.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Cálcio , Colagem Dentária , Resinas Epóxi/química , Teste de Materiais , Dente Molar , Materiais Restauradores do Canal Radicular/química , Silicatos , Ondas Ultrassônicas
2.
Int Endod J ; 54(7): 1166-1174, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33556198

RESUMO

AIM: To evaluate in a laboratory setting the performance of two reciprocating glide path systems, WaveOne Gold Glider (WO) and R-Pilot (RP), to create a glide path in mesial root canals of mandibular molars and to assess the torsional resistance of instruments after performing the glide path. METHODOLOGY: A total of 60 mesial root canals of extracted human mandibular molars were divided into two groups (n = 30) according to the glide path system to be used. The data from the volume of each canal, acquired by microcomputed tomography (micro-CT), were validated statistically for the anatomical pairing of the groups. Preparation time, frequency in gaining apical patency, plastic deformation rate of instruments, and canal transportation and centring ability were recorded and compared statistically. The torsional fatigue of the instruments after use was also evaluated. Data were analysed using Fisher's exact test and Mann-Whitney U-test with a 5% significance level. RESULTS: No significant differences were found between groups regarding the time required to perform the glide path, the frequency distributions of the canals classified as patent and the instruments with plastic deformation after use (P > 0.05). No significant differences were found between groups regarding the degree of canal transportation and centring ability at the cervical, middle and apical thirds (P > 0.05). The RP groups had significantly greater maximum torsional strength values compared with the WO groups (P < 0.05). The used WO group had greater angular deflection to fracture when compared to the new WO group (P < 0.05). A significant difference was also found in the percentage of loss of angular deflection in a comparison of the WO group with the RP group (P < 0.05). CONCLUSIONS: The WO and RP instruments performed the same in terms of preparation time, plastic deformation, gaining apical patency, degree of canal transportation and centring ability. The RP instruments had greater torsional strength, less angular deflection and lower percentage of loss in angular deflection than the WO. The used WO group had the greatest angular deflection values.


Assuntos
Cavidade Pulpar , Laboratórios , Instrumentos Odontológicos , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Humanos , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Preparo de Canal Radicular , Estatísticas não Paramétricas , Titânio , Microtomografia por Raio-X
3.
Int Endod J ; 54(4): 616-627, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33219520

RESUMO

AIM: To assess the free available chlorine concentration (FAC), organic tissue dissolution and smear layer removal capacity of sodium hypochlorite (NaOCl) alone and when mixtured with etidronate (HEDP) and tetrasodium EDTA (Na4 EDTA), and heated to different temperatures. METHODOLOGY: Mixtures at 1 : 1 ratio of 5% NaOCl with distilled water (considered NaOCl alone), 18% HEDP or 10% Na4 EDTA were heated to 25 °C, 37 °C, 48 °C and 60 °C. The FAC in the mixtures was assessed at 5, 10, 20, 30, 60 and 120 min. Samples of bovine muscle tissue (n = 10) were prepared with similar size and weighed before and after 5, 10 and 15 min of immersion in the mixtures heated to the different temperatures to verify organic matter dissolution. The intergroup results were compared statistically using one-way analysis of variance (anova) and intragroup by two-way analysis of variance (anova), both followed by Tukey's multiple-comparison test (α < 0.01). Bovine dentine blocks (n = 10) were analysed by scanning electron microscopy before and after immersion in the mixtures, and the time taken to remove the smear layer from the surfaces of the samples was determined. The Friedman test was used to compare the scores of the same group (α < 0.01), and the Kruskal-Wallis test with Dunn's post hoc was used to compare the different groups (α < 0.01). Saline solution was used as a control in the experiments of tissue dissolution and smear layer removal, RESULTS: Heating NaOCl alone did not affect its FAC. The higher the temperature of the mixtures with the chelators, the lower the FAC. Organic tissue dissolution was improved by increases in temperature of NaOCl alone and its mixture with HEDP (P < 0.01); however, the mixture with Na4 EDTA had no improvement (P > 0.01). Smear layer removal by NaOCl alone was enhanced by heating resulting in lower scores in some samples and became more rapid in the mixtures with the chelators. The saline solution did not promote tissue dissolution nor smear layer removal (P > 0.01). CONCLUSION: In this laboratory study, heating NaOCl alone or when mixed with HEDP improved its capacity to dissolve organic matter and remove the smear layer. However, the mixture with HEDP required frequent refreshment to retain these effects when heated. Due to the acceleration in the reaction between the irrigants, very rapid reductions in the free available chlorine in the mixtures with Na4 EDTA heated to the different temperatures occurred.


Assuntos
Ácido Etidrônico , Camada de Esfregaço , Animais , Bovinos , Cavidade Pulpar , Dentina , Ácido Edético/farmacologia , Ácido Etidrônico/farmacologia , Temperatura Alta , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular , Preparo de Canal Radicular , Hipoclorito de Sódio/farmacologia
4.
Int Endod J ; 53(3): 366-375, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31566756

RESUMO

AIM: To evaluate the effectiveness of five instruments used for irrigant agitation during the removal of calcium hydroxide [Ca(OH)2 ] paste in simulated internal root resorption (IRR) cavities created in extracted maxillary central incisors. METHODOLOGY: Seventy maxillary central incisors with a single canal were selected. The canals were accessed and instrumented with Reciproc R50, then the roots were split in the bucco-lingual direction and the halves separated. Simulated IRR cavities were created, in both halves of the roots, 5 mm from the apex with a spherical bur. The specimens were reconstructed with cyanoacrylate glue and allocated into seven groups: negative control - no treatment; positive control - filled with Ca(OH)2 without performing any irrigation protocol; the other groups were divided according to the instrument used for irrigant agitation, namely: Ultrasonic, EndoActivator® , EDDY® , XP-endo® Finisher and XP-endo® Shaper. The specimens were cleaved and analysed using optical microscopy and scanning electron microscopy, to compare the Ca(OH)2 remnants between them. Then, the IRR cavities created by the burs were cleaned and subjected to a protocol of demineralization with 20% nitric acid, the roots reconstructed, and the irrigant agitation methods, as well as the microscopic analysis was repeated. Analysis of the images of Ca(OH)2 remaining in the simulated IRR cavities after irrigation was performed by two calibrated examiners based on a previously established scoring system. The data were statistically compared by Kruskal-Wallis test, Mann-Whitney U-test and Wilcoxon tests, with the significance level set at 5%. RESULTS: There was a significant difference in the effectiveness of the instruments in relation to the cavity creation method (bur vs. bur/acid) and evaluation method (optical microscopy and scanning electron microscopy) (P < 0.05). The XP-endo® Finisher and EDDY® groups were associated with significantly more effective removal of Ca(OH)2 when the IRR cavities were created using the acid protocol and analysed by scanning electron microscopy. CONCLUSION: None of the instruments tested were able to completely remove the Ca(OH)2 paste from the simulated IRR cavities; however, the EDDY® and XP-endo® Finisher removed more Ca(OH)2 in the bur/acid cavity creation method analysed by scanning electron microscopy.


Assuntos
Cárie Dentária , Reabsorção da Raiz , Hidróxido de Cálcio , Cavidade Pulpar , Humanos , Incisivo , Irrigantes do Canal Radicular , Preparo de Canal Radicular , Irrigação Terapêutica
5.
Int Endod J ; 52(11): 1652-1659, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31132158

RESUMO

AIM: To evaluate the influence of larger apical canal enlargement in curved canals using reciprocating systems subjected to various heat treatments. METHODOLOGY: Ninety mandibular premolars with root curvatures ranging from 20° to 30° were selected and scanned by microcomputed tomography (micro-CT) before and after root canal preparation with reciprocating systems (n = 30): Reciproc Blue (RB size 25, .08 taper and size 40, .06 taper; VDW, Munich, Germany), WaveOne Gold (WOG size 25, .07 taper and size 35, .06 taper; Dentsply Sirona, Ballaigues, Switzerland) and ProDesign R (PDR size 25, .06 taper and size 35, .05 taper; Easy Dental Equipment, Belo Horizonte, Brazil). Canal transportation, untouched areas, and apical and total root canal volumes were measured. Statistical analysis was performed with the nonparametric Kruskal-Wallis and Dunn's tests and a significance level set at 5%. RESULTS: The between-group comparison revealed no significant difference in untouched areas, canal transportation, and apical root canal volume among the groups (P > 0.05). However, WOG size 35, .06 taper was associated with a significant increase in the percentage of total canal volume in comparison to the PDR size 35, .05 taper (P < 0.05). The within-group comparison revealed a significant decrease in untouched areas, increase in apical and total root canal volume for all groups when using a larger instrument (P < 0.05). There was no significant difference in transportation among the groups and when a larger apical preparation was created (P > 0.05). CONCLUSIONS: Larger apical enlargement of curved canals was associated with a decrease in untouched areas, an increase in root canal volume and maintenance of canal trajectory. In addition, all systems were safe and provided similar root canal shapes.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Brasil , Cavidade Pulpar , Desenho de Equipamento , Alemanha , Preparo de Canal Radicular , Microtomografia por Raio-X
7.
Int Endod J ; 52(6): 847-856, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30548555

RESUMO

AIM: To evaluate the influence of three engine-driven NiTi file systems manufactured from different NiTi alloys for the preparation of second mesiobuccal (MB2) canals in extracted maxillary first molars using a micro-computed tomographic (micro-CT) scanner. METHODOLOGY: Thirty maxillary molars with two canals in the mesiobuccal root were selected and randomly divided into three groups (n = 10): Reciproc [REC; size 25, .08 taper; VDW, Munich, Germany], ProDesign R [PDR; size 25, .06 taper; Easy, Belo Horizonte, Brazil] and Mtwo [MO; size 25, .06 taper; VDW, Munich, Germany]. Before and after root canal preparation of the MB2 canal, the teeth were scanned using a micro-CT to evaluate canal transportation, centring ability, dentine thickness and volume change. The working time to achieve working length was also evaluated. All parameters were compared statistically using the Kruskal-Wallis and Dunn test for multiple comparisons, with a significance level of 5%. RESULTS: There was no significant difference amongst the groups regarding canal transportation and centring ability (P > 0.05). However, the PDR size 25, .06 taper group had significantly lower canal volume and volume of dentine removal compared with a MO size 25, .06 taper and REC size 25, .08 taper (P < 0.05). A root perforation was detected in MO size 25, .06 taper and REC size 25, .08 taper groups, respectively. Regarding the working time, the PDR size 25, .06 taper required a significantly longer time to achieve working length than MO size 25, .06 taper and REC size 25, .08 taper (P < 0.05). CONCLUSIONS: All NiTi systems had similar canal transportation, centring ability and increase in apical volume after preparation of MB2 canals. However, the PDR size 25, .06 taper had less volume of dentine removal, absence of root canal perforation and required a longer time to accomplish the root canal preparation.


Assuntos
Níquel , Titânio , Ligas , Brasil , Cavidade Pulpar , Alemanha , Dente Molar , Preparo de Canal Radicular , Microtomografia por Raio-X
8.
Int Endod J ; 51 Suppl 1: e42-e54, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28306162

RESUMO

AIM: To investigate the effects of several decalcifying agents alone and in combination with sodium hypochlorite (NaOCl) on the organic and inorganic components of dentine using attenuated total reflectance in Fourier transform infrared spectroscopy (ATR-FTIR). METHODOLOGY: Dentine slices from bovine teeth were submitted to (n = 5) the following: 0.9% saline, 9% and 18% etidronic acid (HEDP), 5% and 10% tetrasodium EDTA (EDTANa4 ), 17% trisodium EDTA (EDTAHNa3 ), and 0.5% and 2.0% peracetic acid (PAA) for 0.5-10 min; and to the combinations: G1 - mixture 5% NaOCl + 18% HEDP (5 and 10 min); G2 - mixture 5% NaOCl + 10% EDTANa4 (5 and 10 min); G2 - 2.5% NaOCl (5 min) + 17% EDTAHNa3 (1 min); G3 - 2.5% NaOCl (5 min) + 0.5% PAA (1 min); G4 - 2.5% NaOCl (5 min) + 9% HEDP (5 min). Specimens of G2, G3 and G4 received final flushes with 2.5% NaOCl for 0.5-10 min. Amide III/phosphate and carbonate/phosphate ratios of the spectra collected from the dentine specimens before and after immersion in the solutions were determined. Data were submitted to one-way repeated measures and one-way anova. RESULTS: For the same decalcifying agent, the higher the concentration and immersion time the greater the removal of phosphate, exposure of collagen matrix and consequently the increases in amide III/phosphate ratio. However, significant differences were found only between the two concentrations of PAA (P < 0.05). PAA caused greater increases in this ratio, followed by EDTAHNa3 , EDTANa4 and HEDP, and this order was retained in the combinations with NaOCl. This ratio was significantly reduced in G1 (P < 0.05) and not altered in G2 (P > 0.05). Due to collagen degradation, the amide III/phosphate ratio reduced significantly after the use of NaOCl in G3, G4 and G5 (P < 0.05). NaOCl required approximately 0.5 s to deproteinate the collagen matrix exposed after phosphate removal by EDTAHNa3 and PAA. The carbonate of dentine was removed more rapidly than phosphate by all decalcifying agents alone and in G3, G4 and G5. In the combinations with NaOCl, the last irrigant used defined the dentine amide III/phosphate and carbonate/phosphate ratios. CONCLUSIONS: HEDP and EDTANa4 caused minor whilst EDTAHNa3 and PAA caused greater demineralization of dentine; both effects were time and concentration dependent. NaOCl degraded the dentine organic matrix more rapidly when it was exposed. Combinations of NaOCl and decalcifying agents can be used to create dentine surfaces with varying compositions for interaction with endodontic sealers.


Assuntos
Dentina/química , Irrigantes do Canal Radicular/farmacologia , Hipoclorito de Sódio/farmacologia , Animais , Bovinos , Dentina/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Desmineralização do Dente/induzido quimicamente
9.
Int Endod J ; 51(6): 705-713, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29178173

RESUMO

AIM: To evaluate apical transportation and centring ability during root canal preparation in mesial root canals of mandibular molars associated with ProTaper Gold (PTG), ProDesign S (PDS), Hyflex CM (HCM), Hyflex EDM and ProDesign Logic (PDL). METHODOLOGY: Sixty mandibular first molars with two separate canals in the mesial root were selected after root anatomy pairing by microcomputed tomography (microCT). The teeth were randomly divided into five groups (n = 24); the root canal volume was calculated to ensure sample homogeneity. All the root canals were prepared up to size 25 in accordance with the instructions of each rotary system manufacturer. After root canal preparation, the teeth were scanned by microCT to analyse apical transportation, root canal centralization and the pre- and post-preparation root canal volume at the apical and cervical levels. Kruskal-Wallis and Dunn tests were used for comparisons amongst groups for transportation values. For volume changes, the parametric ANOVA and Tukey's tests were used RESULTS: There were no significant differences in apical transportation amongst the rotary systems (P > 0.05). All the systems created apical transportation; values ranging from 0.031 mm (PDL) to 0.072 mm (PTG), and enlargements between 39% (HCM) and 91.1% (PDS) were observed. In relative to cervical transportation, significant differences were observed amongst the systems (P < 0.05). Mean transportation values between 0.07 mm (HCM) and 0.172 mm (PTG) were found, with enlargements between 35.4% (HCM) and 51.5% (PDS). CONCLUSION: All the thermally treated systems resulted in similar apical transportation. In the cervical region, the Hyflex CM and Prodesign Logic systems were associated with more centred preparations.


Assuntos
Ligas Dentárias/química , Instrumentos Odontológicos , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Temperatura Alta , Humanos , Técnicas In Vitro , Teste de Materiais , Dente Molar , Propriedades de Superfície , Microtomografia por Raio-X
10.
Int Endod J ; 51(6): 697-704, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29171880

RESUMO

AIM: To evaluate the torsional properties of pathfinding nickel-titanium (NiTi) rotary instruments manufactured from several NiTi alloys, ProGlider (M-wire), Hyflex GPF (conventional NiTi Wire and controlled memory wire), Logic (conventional NiTi wire and controlled memory wire) and Mtwo (conventional NiTi wire). METHODOLOGY: A total of 56 NiTi instruments from Glidepath rotary systems (n = 8) were used: Logic (size 25, .01 taper), Logic CM (size 25, .01 taper), ProGlider (size 16, .02 taper), Hyflex GPF (size 15, .01 taper), Hyflex GPF CM (size 15, .02 taper; size 20, .02 taper) and Mtwo (size 10, .04 taper). The torsion tests were performed based on ISO 3630-1 (1992). Three millimetres of each instrument tip was clamped to a small load cell by a lever arm linked to the torsion axis. Data were analysed using a one-way analysis of variance (anova) and Tukey test with a significance level at a = 5%. RESULTS: The Logic size 25, .01 taper had significantly higher torsional strength values (P < 0.05). The ProGlider was significantly different when compared with Hyflex GPF size 15, .01 taper and size 15, .02 taper (P < 0.05). The Logic CM size 25, .01 taper had significantly higher torsional strength than Hyflex GPF size 15, .01 taper and size 15, .02 taper (P < 0.05). No difference was found amongst Mtwo size 10, .04 taper and Hyflex GPF groups (size 15, .01 taper; size 15, .02 taper; size 20, .02 taper). In relation to the angle of rotation, Logic CM size 25, .01 taper and Hyflex GPF size 15, .01 taper had the highest angle values (P < 0.05). The ProGlider had the lowest angle values in comparison with all the groups (P < 0.05) followed by Mtwo size 10, .04 taper. The Logic size 25, .01 taper had significantly higher angle of rotation values than ProGlider and Mtwo size 10, .04 taper (P < 0.05). CONCLUSION: The Logic size 25, .01 taper instrument made of conventional NiTi alloy had the highest torsional strength of all instruments tested. In addition, the ProGlider instrument manufactured from M-Wire alloy had the lowest angle of rotation to fracture in comparison with the other instruments.


Assuntos
Ligas Dentárias/química , Instrumentos Odontológicos , Níquel/química , Titânio/química , Torção Mecânica , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Tratamento do Canal Radicular/instrumentação , Estresse Mecânico
11.
Int Endod J ; 49(9): 890-897, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26280904

RESUMO

AIM: To use micro-CT to quantitatively evaluate the amount of residual filling material after using several techniques to remove root fillings with and without ultrasonic activation and to analyse the cleanliness of the root canal walls and dentine tubules with scanning electron microscopy (SEM). METHODOLOGY: The root canals of one hundred and eight human mandibular incisors were selected and instrumented with rotary files using the BioRace system up to file size 40, .04 taper. After instrumentation, the teeth were filled using a hybrid technique with gutta-percha and sealer then divided into three groups according to the method used for removing the root filling: G1-Reciproc (using only instrument R50), G2-ProTaper Universal retreatment system and G3-Manual (hand files and Gates-Glidden burs). All groups were divided into two subgroups depending on whether ultrasonic agitation was used with the irrigants. Micro-CT scans were taken before and after removal of the filling material to detect residual material in the canal. After micro-CT analysis, the roots were cut in half, imaged by SEM and scored based on the amount of surface covered by root filling remnants. The data were analysed statistically using a significance level of 5%. RESULTS: All groups had retained material in the root canals after instrumentation. The Reciproc method was associated with less retained material than the ProTaper and Manual methods. Ultrasonic activation significantly reduced the amount of residual root filling in all groups (P < 0.05). CONCLUSION: None of the instrumentation methods were able to completely remove root filling material. Ultrasonic activation improved the removal of root filling material in all groups.

12.
Int Endod J ; 45(6): 565-70, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22720325

RESUMO

AIM: To evaluate the influence of propylene glycol (PG) on the flowability, setting time, pH and calcium ion release of mineral trioxide aggregate (MTA). METHODOLOGY: Mineral trioxide aggregate was mixed with different proportions of PG, as follows: group 1: MTA + 100% distilled water (DW); group 2: MTA + 80% DW and 20% PG; group 3: MTA + 50% DW and 50% PG; group 4: MTA + 20% DW and 80% PG; group 5: MTA + 100% PG. The ANSI/ADA No. 57 was followed for evaluating the flowability and the setting time was measured by using ASTM C266-08. For pH and calcium release analyses, 50 acrylic teeth with root-end cavities were filled with the materials (n = 10) and individually immersed in flasks containing 10 mL deionized water. After 3 h, 24 h, 72 h and 168 h, teeth were placed in new flasks and the water in which each specimen was immersed had its pH determined by a pH metre and the calcium release measured by an atomic absorption spectrophotometer with a calcium-specific hollow cathode lamp. Data were analysed by using one way anova test for global comparison and by using Tukey's test for individual comparisons. RESULTS: The highest value of flowability was observed with MTA + 20% DW and 80% PG and the lowest values were found with MTA + 100% DW. They were significantly different compared to the other groups (P < 0.05). The presence of PG did not affect the pH and calcium release. The MTA + 100% PG favoured the highest (P < 0.05) pH and calcium release after 3 h. Increasing the PG proportion interfered (P < 0.05) with the setting time; when used at the volume of 100% setting did not occur. CONCLUSION: The addition of PG to MTA-Angelus increased its setting time, improved flowability and increased the pH and calcium ion release during the initial post-mixing periods. The ratio of 80% DW­20% PG is recommended.


Assuntos
Compostos de Alumínio/química , Compostos de Cálcio/química , Óxidos/química , Veículos Farmacêuticos/química , Propilenoglicol/química , Silicatos/química , Cálcio/química , Fenômenos Químicos , Combinação de Medicamentos , Dureza , Humanos , Concentração de Íons de Hidrogênio , Eletrodos Seletivos de Íons , Teste de Materiais , Reologia , Espectrofotometria Atômica , Fatores de Tempo , Viscosidade , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...